Controllers
6.6 Connecting terminals and interfaces
AT40, ATD400V, ATD400K, ATD4xxW, ATD400S, ATE250S, ATD400T
System Manual, 06/2016, A2B00096162-AN
157
Connection
The wired RJ45 connectors are connected to the two X1000 Port 1 and X1000 Port 2
terminals.
6.6.6.6
Wiring and connecting relay outputs
Wiring
The USS, PROFIBUS and PROFINET modules have 2 relay outputs (NO contacts).
Maximum voltages of 42.0
V (peak value, ≙
29.6 V
rms
in the case of sinusoidal voltage (SELV
acc. to EN60950-1)) may be applied to the relevant module.
Contact rating of the relay outputs:
●
DC max: 30 V DC, 500 mA
●
AC max: 29.6 V AC, 500 mA, sinusoidal (limited due to the fact that only SELV is
permissible on the module)
The matching 4-pole mating connector (PHOENIX MC1.5/4-ST-3.81) with the screw
terminals is delivered along with the module (plugged in).
The pin assignments are: