Connecting and commissioning
AT40, ATD400V, ATD400K, ATD4xxW, ATD400S, ATE250S, ATD400T
System Manual, 06/2016, A2B00096162-AN
281
Procedure
Preparing
1.
Push the door into the CLOSED position.
2.
Open the housing cover.
Connecting the geared motor
1.
Connect the motor plug(s) as follows:
–
①
SIDOOR AT40, ATD400K, AT400S, ATD400V, ATD400W, ATD4xxW: Slot X7 on
the controller
–
②
SIDOOR ATE250S: Slot X4201 for the motor windings and X7000 for the sensor
signals on the controller
Note
SIDOOR AT40, ATD400K, AT400S, ATD400V, ATD400W, ATD4xxW
The X6 control inputs plug is not plugged in during commissioning in order to prevent
uncontrolled movements.