Controllers
6.7 Parameters
AT40, ATD400V, ATD400K, ATD4xxW, ATD400S, ATE250S, ATD400T
172
System Manual, 06/2016, A2B00096162-AN
Parameter ID
Unit
Parameter name
Description
p3681
mA
Cutter press-on torque
Cutter press-on torque in the closed position for ap-
prox. 2 s
Forces
p3682
N
Static opening force
Static opening force
p3683
N
Static closing force
Static closing force
p3684
N
Static cutter force CLOSE
Static cutter force in the closing direction
p3685
N
NDG force (reduced) static
Force in NDG mode in the opening and closing direc-
tions
You will find the corresponding factory settings and adjustment ranges (depending on the
motor used) for the driving parameters in Section Profiles and adjustment ranges
(Page 296).
6.7.3.2
Other parameters
Table 6- 38 Other parameters
Parameter ID Adjustment range
Factory
setting
Unit
Description
Sensor Module
p4600
0 ≙ inactive
1 ≙ OSSD
2 ≙ DCOPS
3 ≙ SR
0
—
Local sensor type
p4601
20 … 5000
30
ms
Discrepancy time in the function test of the OSSD
system
p4610
10 … 30000
0 ≙ "AND0" discrepancy
analysis deactivated
400
ms
Discrepancy analysis time of the input monitoring
block FBLOCK "AND0"
Faults and alarms
r2100
—
—
—
Status code
ASCII code of the 7-segment display (see Section
Operating state display (Page 183))
r2101
—
—
kg
Effective door weight
r2102
0 ≙ special motor
1 ≙ M2
2 ≙ M3 / MDG180
3 ≙ M4 / MDG400
4 ≙ M5
255 ≙ unknown motor
Connected motor
r2103
—
—
mm
Currently learnt door width
r2104
—
—
[N]
System friction in the opening direction determined
during the learn run (the friction of the drive system
is not included here)