Standard for EMC
EN 12015:2004 / EN
12016:2009 / EN
61000-6-4:2011 / EN
61000-6-2:2006 / EN
50121-3-2:2006 /
50121- 5:2007
EN 61000-6-2 / EN
61000-6-4
EN 50121-3-2
Certificate of suitability
CE marking
Yes
Yes
Yes
Standard for safety
EN 60950-1:2011
ISO 13849-1 PLd
CAT2
—
Note
SIDOOR ATD400T relay (6FB1121-0BM13-3AT2) – supplementary technical specifications
•
Maximum output current at 24 V DC:
–
0.4
A at ≤
55 °C ambient temperature during operation
–
0.1 A from 55 °C to 70 °C ambient temperature during operation, with restrictions at
operating temperatures > 55 °C
•
Maximum ambient temperature during operation:
–
55 °C
–
70 °C with restrictions at operating temperatures > 55 °C
•
Restrictions at operating temperatures > 55 °C:
–
Use the 24 V output voltage only for operating the control inputs (max. 0.1 A)
–
Use a sufficiently large (at least 350 x 350 mm), unpainted, metal mounting plate
–
The maximum drive parameters are restricted to the default values
–
If temperature class T3 according to EN 50155 is used, the maximum air temperature
of 85 °C must not be exceeded near the printed-circuit board