Connecting and commissioning
AT40, ATD400V, ATD400K, ATD4xxW, ATD400S, ATE250S, ATD400T
284
System Manual, 06/2016, A2B00096162-AN
6.
The display on the controller is as follows:
–
The 7-segment display (H401) shows "H.". The decimal point in the 7-segment display
(H401) flashes during the save process.
The 7-segment display (H401) shows "u" when saving has finished. If a light
barrier/pressure-sensitive edge
2)
is used, the 7-segment display (H401) shows "0."
because X6 is not yet connected. For the M4, MDG400. MDG400NMS and M5
motors, the determined door weight is shown on the LCD for the initial commissioning
or motor adaptation.*
* SIDOOR ATD4xxW
–
The LCD display (H1) shows "'H': learn run activated".
The LCD display (H1) finally shows "'u': door is closed".
1)
7.
The door can now be opened with the OPEN button (S402 / S2
1)
)
–
The 7-segment display (H401) shows "o" while the door is opening.
–
During the opening, the LCD display (H1) shows "'o': error-free".
1)
8.
Switch off the controller by pulling out the power plug or the connector X3 / X1000
1)
.
Connecting the SIDOOR AT-EB expansion unit (optional, only with SIDOOR ATD400S and
ATE250S)
1.
Connect the controller to the SIDOOR AT-EB expansion unit via the serial interface
(connector X8).
Only use a recommended connecting cable. See Section Accessories (Page 23).