Appendix
A.1 Profiles and adjustment ranges
AT40, ATD400V, ATD400K, ATD4xxW, ATD400S, ATE250S, ATD400T
318
System Manual, 06/2016, A2B00096162-AN
A.1.8.1
SIDOOR ATD4xxW
The default values are automatically set to the high limit when the high limit is exceeded.
Accordingly, the actual default values may differ from the default values in the table below.
Table A- 19 Parameters SIDOOR MDG400NMS L / R
Parameters
Parameter ID Unit
Profile 1*
Creep distance OPEN
p3660
mm
30
Cutter distance OPEN
p3661
mm
30
Creep distance CLOSE
p3662
mm
20
Cutter distance CLOSE
p3663
mm
40
Maximum speed OPEN
p3664
mm/s
600
Creep speed OPEN
p3665
mm/s
40
Cutter speed OPEN
p3666
mm/s
60
Initial speed OPEN
p3667
mm/s
90
Maximum speed CLOSE
p3668
mm/s
177
Creep speed CLOSE
p3669
mm/s
60
Cutter speed CLOSE
p3670
mm/s
40
Initial speed CLOSE
p3671
mm/s
90
NDG speed (reduced)
p3672
mm/s
177
Acceleration ramp OPEN
p3673
mm/s2 1300
Braking ramp OPEN
p3674
mm/s2 600
Reverse ramp OPEN/CLOSE
p3675
mm/s2 1200
Acceleration ramp CLOSE
p3676
mm/s2 500
Braking ramp CLOSE
p3677
mm/s2 500
Reversing ramp CLOSE/OPEN
p3678
mm/s2 850
Continuous torque (power) OPEN p3679
A
1
Continuous torque (power) CLOSE p3680
A
1
Cutter press-on torque
p3681
A
3
Static opening force
p3682
N
75
Static closing force
p3683
N
75
Static cutter force CLOSE
p3684
N
75
Static NDG force (reduced)
p3685
N
75
Limit energy close
p1202
J
4
Limit energy open
p1203
J
4
Limit energy NDG
p1204
J
4
* Default profile (this profile is automatically loaded at the first commissioning)