Controllers
6.7 Parameters
AT40, ATD400V, ATD400K, ATD4xxW, ATD400S, ATE250S, ATD400T
System Manual, 06/2016, A2B00096162-AN
179
Parameter ID
Adjustment range
Factory setting Unit
Description
p3874
1)
0 … 60000
10
mm
Range of suppression of obstruction detection
before the open end stop
p3875
1)
0 … 60000
20
mm
Range of suppression of force obstruction detec-
tion before the creep distance
p3876
1)
0 … 60000
50
mm
Range of suppression of force obstruction detec-
tion after the last obstruction
Retries
p3877
0 to 0xFFFF
0 ≙ no retry
0xFFFF ≙ unlimited
retries
3
0 (V1.03 and
higher)
—
Number of retries to overcome the obstruction
p3878
0 … 60000
2000
ms
Wait time before each retry
p3879
0 ≙ deenergize
1 ≙ stop
0
—
Drive control during the wait time (before retries)
p3880
0 ≙ deenergize
1 ≙ stop
2 ≙ open
3 ≙ close
0
—
Drive control after all retries have been executed
(if reversing is not configured)
Reversing
p3881
0 to 0xFFFF
0 ≙ no reversing
0xFFFF ≙ unlimited
reversing
0
1 (V1.03 and
higher)
—
Number of reverses
p3882
0 … 60000
2000
ms
Wait time before each reverse
p3883
0 … 60000
0 ≙ full reverse
0
200 (V1.03
and higher)
mm
Reversing distance
p3884
0 ≙ deenergize
1 ≙ stop
2 ≙ open
3 ≙ close
0
—
Drive control for obstruction while reversing
p3885
0 ≙ deenergize
1 ≙ stop
2 ≙ open
3 ≙ close
0
—
Drive control after all reverses have been execut-
ed
1)
Expert parameters, see Section Expert configuration (Page 64).