Controllers
6.7 Parameters
AT40, ATD400V, ATD400K, ATD4xxW, ATD400S, ATE250S, ATD400T
170
System Manual, 06/2016, A2B00096162-AN
Static cutter force CLOSE
This force serves to overcome the cutter distance in the closing direction.
A higher force is often required to overcome the cutter distance than for the rest of the
distance the door travels.
This parameter is effective in the closing direction when the door is within the cutter distance.
Adjustment ranges
The parameter can be adjusted in accordance with the adjustment ranges of the parameters
(see Section Profiles and adjustment ranges (Page 296)). The value of the parameter must
be selected so that the cutter distance is overcome in the closing direction.
Static nudge force CLOSE
This force is effective during the closing movement if a nudge command is present.
Adjustment ranges
The parameter can be adjusted in accordance with the adjustment ranges of the parameters
(see Section Profiles and adjustment ranges (Page 296)). The value of the parameter must
be selected so that, if a nudge command is present, the door moves across the entire door
width in the closing direction. Inadequate force can lead to an obstruction of the door.
6.7.3
Parameter assignment (ATD4xxW)
The tables below show all the parameters that are available via the PKW interface. The
parameters are generally subdivided into:
●
Driving parameters
●
Fieldbus parameters
●
Other parameters
●
Calibration and function parameters
●
Obstruction and reversing parameters
●
FBLOCK parameters
Note
Write-protected parameters (read only) are indicated in the documentation by an "r" before
the parameter number.
Read / write parameters can be changed, and are indicated by a "p" before the parameter
number.