Controllers
6.16 Technical specifications
AT40, ATD400V, ATD400K, ATD4xxW, ATD400S, ATE250S, ATD400T
System Manual, 06/2016, A2B00096162-AN
227
Order number
6FB1141-1AT11-
3WE2
6FB1141-4AT10-
3WE2
6FB1141-2AT10-
3WE2
6FB1141-3AT10-
3WE2
Output current
•
at 24 V DC output /
maximum
mA
400
Property of the 24 V DC out-
put
•
Short-circuit proof
Yes
•
with overload with-
stand capability
Yes
Switching capacity current / of
the output relay
•
at DC / at 30 V
A
0.01 ... 1
0.01 ... 0.5
Door-relevant data:
Door opening width
m
0.3 ... 5
Weight / of door / maxi-
mum
kg
600
Opposing force / maxi-
mum
N
75
Operating cycle frequency
/ of door / maximum
1/h
180
Kinetic energy / maximum J
100
Communication:
Design of the interface
without
USS according to
EIA 485, IEC
61800-7-200 Type
3
PROFIBUS ac-
cording to IEC
61784-3
PROFINET IO
according to Con-
formance Class C
Number of bus nodes
32
Ambient conditions:
Ambient temperature
•
during operation
°C
-20 ... +50
•
during operation / Note
Screw control
device thermally
conductive onto a
metallic mounting
surface or stand-
ard rail mounting ,
otherwise the
maximum operat-
ing temperature is
only 40 °C
•
during storage
°C
-40 ... +70
Relative humidity / without
condensation
%
10 ... 93
Installation altitude / at
height above sea level /
maximum
m
2 000
Protection class IP