Controllers
6.4 Operation and parameter assignment
AT40, ATD400V, ATD400K, ATD4xxW, ATD400S, ATE250S, ATD400T
System Manual, 06/2016, A2B00096162-AN
113
6.4.1.2
Minimal editor
Using the minimal editor
SIDOOR AT40, ATD400V, ATD400K, ATD400W, ATD400S and ATD400T controllers have
a minimal editor.
The minimal editor is a tool for changing the parameters of a controller if the terminal
module, SIDOOR Service Tool or SIDOOR User Software are not available. In this case, the
learn run button (S401) and the two service buttons (S402, S403) are assigned second
functions. The LED display (H401) is used to visualize messages.
You can use the minimal editor to perform the following settings:
●
Select a fixed profile
●
Set the closing forces (input of the counterweight)
WARNING
Risk of injury due to moving mechanical parts
Selecting a profile overwrites the input of the counterweight.
For this reason, set the value for the counterweight (parameter 'A') last.
The minimal editor can only be activated by pressing the service buttons S401 and S402 at
the same time as the network is reset.
Activating the minimal editor
1.
Disconnect the controller from the power supply by unplugging the power plug.
The line voltage can alternatively be connected and disconnected with the X3 connector
directly on the controller.
2.
Press and hold down the S402 and S403 buttons simultaneously and reestablish the line
voltage by plugging the power plug back in. Continue to hold down both buttons.
3.
An "8" appears on the LED display for approximately 5 seconds as confirmation.
4.
Once the display stops, let go of both buttons within approximately 3 seconds. Do not
touch the buttons again during this time period.
5.
To confirm the successful activation of the minimal editor, the LED display alternates
between a "C" and the currently assigned profile in the form of a number from 1 to 6.