7ML19985FC03
HydroRanger 200 – INSTRUCTION MANUAL
Page 3
mm
mmm
Specificat
io
ns
Specifications
Power
AC version
• 100-230 V AC ± 15%, 50 / 60 Hz, 36 VA (17W)
1
• fuse: F3: 2 AG, Slow Blow, 0.375A, 250V
DC version
• 12-30 V DC, 20W
1
• fuse: F3: 2 AG, Slow Blow, 2A, 250V
Transmitter fuse
• F1: Belling Lee, L754, 4000A HRC, ceramic type, 100mA, 250V
Temperature Sensor fuse
• F2: Belling Lee, L754, 4000A HRC, ceramic type, 50mA, 250V
Mounting
Location
• indoor / outdoor
Altitude
• 2000 m max.
Ambient temperature
• -20 to +50 °C (-5 to +122 °F)
Relative humidity
• Wall Mount: suitable for outdoors (Type 4X / Nema 4X, IP65 Enclosure)
• Panel Mount: suitable for outdoors (Type 3 / Nema 3, IP54 Enclosure)
Installation category
• II
Pollution degree
• 4
1.
Power consumption is listed at maximum.