Operating Instructions
Chapter
3
Flexi Classic Gateways
8011834/YT28/2016-03-15
© SICK AG • Industrial Safety Systems • Germany • All rights reserved
17
Subject to change without notice
Flexi Classic gateways
3.2.12
MQD
Module status and output data (output states/module output data)
Bit 7
6
5
4
3
2
1
Bit 0
UE410-MU
UE410-XU
BYP
MUTE
StRq B
StRq A
Q4
Q3
Q2
Q1
UE410-GU
O
P
O
N
StRq
local
StRq
global
Q2
Q2
Q1
Q1
UE410-8DI
-
-
–
–
Q
B
–
Q
A
–
UE410-MM
UE410-XM
OVR
MUTE
OVReq
StRq
Q4
Q3
Q2
Q1
UE410-MDI
–
–
–
–
S4
OVR
CS
C1
With the UE410-MU/XU, the functions StRq A and MUTE are output on Q3 in program 3.
For this reason you would be better using the status bits 4 and 7 for the output of these
states.
Q1-Q4
Output states UE410-MU/
UE410
F
GU/UE410-XU/UE410-MM/
UE410-XM
0 = Output is inactive
1 = Output is active
Module output data UE410-8DI
0 = Output is inactive
1 = Output is active
Q
A
, Q
B
Q
A
/ Q
B
are set if:
• all inputs on the function group (A or B) are in the valid ON state
• the OR function is valid
• the bypass function is valid
Module output data UE410-MDI
0 = Output is inactive
1 = Output is active
S4, OVR, CS, C1
Module output data are the same as module input data.
See module input data (input states)
OVR Req
(only UE410
@
MM/XM)
Override request, waiting for
override
0 = Not currently waiting
1 = The System is in the Override
required state and is expecting the
actuation of the restart button
StRq A,
StRq B
Reset request, waiting for reset
input group A/B
0 = Not currently waiting
1 = Waiting for a reset signal; is
deleted, once the reset has been
made
StRq
Reset request, waiting for reset
0 = Not currently waiting
1 = Waiting for a reset signal; is
deleted, once the reset has been
made
StRq local,
StRq global
(only UE410-GU)
Reset request, waiting for local
reset, waiting for global reset
0 = Not currently waiting
1 = Waiting for a reset signal; is
deleted, once the reset has been
made
Tab. 13: MQD