Flexi Classic gateways
ErrCode for ErrClass 09h:
01 Modules
incompatible
02
Configuration change detected
09
SDO client invalid state
0A Unknown
SDO-cnf
0B Unused
SDO
index
0C
SDO7 in slot list missing for at least 1 module
0D
Index error in slot list
0E
Invalid position switch 0
0F
Invalid position switch 1
10
CRC monitoring module list
11
Monitoring time range constant
12 SALI
monitoring
event
14
Extension unit has emergency bit set
15
Main unit has high emergency bit set
16
Program execution error
17
Slot list in extension module is faulty
18
System tick exceeded
19
Slot index error
1A
Enter key not released while LED was flashing
1C External
error
hardware
reset
1D
Illegal error Opcode Reset
1E
Error Clock generator reset
1F Unexpected
reset
20 Unknown
mask
revisions
21
Error Clock generator loss of lock
41
Cross comparison input configuration erroneous
42
Cross comparison output state erroneous
81
Too many modules found
82
Unknown module ID found
83 Invalid
jumper
S1
84 Invalid
jumper
S2
85 Invalid
jumper
S3
86 Erroneous
module
configuration
87
Rotary switch changed during operation
88
Incomplete data frame on IndexAssign