Distance and angle measurement
9-58
9
6
MEAS.PROG.COND
(conditions of measurement program)
· The sequence when GRAY&EDGE are selected
· The sequence when GRAV (center of gravity) is selected
Starting point number
[Gray scale search]
[Edge detection]
1
MEAS SELECTION
Select the GRAY&EDGE
or GRAV on the DST&AGL
MES. line
7
EVALUATION
COND
(evaluation
conditions)
8
NUMERIC CALC COND
(numerical
calculation condition)
9
OUTPUT
CONDITIONS
Conditions for the
starting point
Conditions for the
starting point
Conditions for the
starting point
These settings are found in the
[TYPE00-MEAS1 to 3] (object type
measurement 1 to 3) menu.
[MAIN OPS MENU]
SET-SCRN
[SYSTEM SETUP]
2
OBJECT TYPE COND
[OBJECT TYPE COND]
0
MEASUREMENT 1
q
MEASUREMENT 2
w
MEASUREMENT 3
2
COMPARE IMAGES
(comparative calculation
between images)
(See page 9.2 [6])
4
COPY,
5
INITIALIZATION
(See page 9.2,
items [7], [8])
3
SELECT CAMERA
(select a camera)
Auxiliary condition
Distance condition
Angle condition
Auxiliary condition
Distance condition
Angle condition
Auxiliary condition
Distance condition
Angle condition
Starting point mode
MAIN OPS MENU
[OBJECT TYPE COND]
e
FINAL CALC RESULT
(final numerical calculations)
(see page 9·2 [4])
[OBJECT TYPE COND]
r
FINAL OUTPUT COND
(final output conditions)
(see "PC function" in
Chapter 10)