Degree of match inspection
9
Reference image
Object to be measured
Continued from the previous page: When the BINRY-IMG-PROC (binary processing mode) is selected.
[Setting sequence for reference criteria]
- This is the sequence to follow when model 1 (object to be measured) is set to NO
[Information about the recording of a reference image]
In order to record a reference image it is necessary to use the freeze frame.
The specifications for a rectangular window are as follows.
[Example of recording]
Return to the [MEASURING COND] (measurement condition) menu and select item
6
UPPER MENU.
Continued on the follwing page
1
REFERENCE
IMAGE
3
THRESHOLD VALUE
2
DETECTED COORD
(detection coordinates)
4
INVERT B/W
(black and white inversion)
9
BINARY PROCESS
(binary conversion process)
q
BINARY NOIS FILTR
(eliminating binary noise)
w
NUM. OF FILTR PASS (the number of cycles that the
binary noise elimination process is applied)
0
IMAGE PRE-PROCESS
(image pre-processing)
e
UPPER MENU
Reference image
Line type
Solid line
Movement
Units of 4 pixels
Size
Units of 4 pixels
Minimum
32
x
32 (pixels)
Maximum
X
x
Y (X
x
Y=65536 pixels)