9·51
Degree of match inspection
9
Continued from page 9·48: When the BINRY-IMG-PROC (binary processing mode) is selected.
Continued on the following page
· You can switch between displaying all of the headings together and displaying each one separately
using the ESC key.
1
REFERENCE IMAGE MOVE UP.L(224,208) LO.R(287,271) REG. DISP
2
DETECTED COORD CNTR
FREE(255,240)
3
THRESHOLD VALUE U.LM
−
255
L.LM
−
100(0~255)
4
INVERT B/W
NO
YES
9
BINARY PROCESS
FIXED
THRSHOLD-ADJ (VAR-DIFF VAR-RATE)
0
IMAGE PRE-PROCESS OFF
SMOOTH
EDGE-EMPHASIS
ALL-EDGE
HORZ-EDGE
VERT-EDGE
q
BINARY NOIS FILTR NO
EXPD.
→
CONTR.
CONTR.
→
EXPD.
w
NUM. OF FILTR PASS EXPD.0(0~5) CONTR0(0~5)
e
UPPER MENU
Menu
1
REFERENCE IMAGE
2
DETECTED COORD
(detection coordinates)
3
THRESHOLD VALUE
4
INVERT B/W
(black and white
inversion)
9
BINARY PROCESS
(the binary conversion
process)
0
IMAGE PRE-PROCESS
(image pre-processing)
q
BINARY NOIS FILTR
(eliminating binary
noise)
w
NUM. OF FILTR PASS
(the number of binary
noise elimination
processing)
e
UPPER MENU
Setting details
Record a reference image.
Set the position of the cursor inside the measurement window.
· If FREE is selected, then position of cursor is optional.
Set the upper and lower limits for binary conversion within the range
of 0 to 255.
-
See page 9·7 “Setting threshold values”, in “Shared settings”
Set the inversion of black and white in the image to YES or NO.
· Selecting NO means that the white area is measured after the
image has been converted to binary values.
· Selecting YES means that the black area will be measured after the
image has been converted to binary values.
Select either fixed or threshold value correction as the binary
conversion processing method. (VAR-DIFF or VAR-RATE).
-
See
page 9·8 “Methods for binary conversion” in “Shared settings”
Select a method for pre-processing the image data.
-
See page 9·9, “Pre-processing” in “Shared settings”
Select a method for eliminating binary noise.
-
See page 9·10, “Methods for eliminating noise from binary images,
expansion/contraction” and, “Eliminating binary noise”, in “Shared
settings”
Separately set the number of cycles that the expansion and
contraction binary noise elimination processes will be repeated (0 to
5).
This will return you to the [MEASURING COND] (measurement
condition) menu.