9-94
Counting quantities by binary convension
9
These displays can be set using
the up and down keys. (The
choices are NO, Y0 to 7, C000
to C127).
· Items
2
to
4
will be displayed if REGST NO. (registration number) is set to YES on the [MEASURING
COND] (mesurement condition) menu.
Measurement window
(rectangular)
Mask window
(rectangular)
· The binary image will be the contents of
the measurement window, after the
portion excluded by the mask window
has been removed.
Continued from the previous page
Continued on the following page
Return to the [TYPE00-MEAS1 to 3] menu and select item
8
NUMERIC CALC COND (numerical calculation conditions).
Return to the [MEASURING COND] menu and select item
3
UPPER MENU.
Select item
7
EVALUATION COND (evaluation condition) on the [TYPE00-MEAS1 to 3] menu.
[EVALUATION COND]
(TYPE00-MEAS.1-CNT-BIN-OBJ)
1
REGST NO.
0(0~3)
[TEST RESULT]
[OUT]
2
NUMBER
0000~3000
00004
OK
NO
3
TOTAL AREA
000000~245760
002000
OK
NO
4
MAKE A TEST RUN (SET KEY)
5
UPPER MENU
· Check your selection by testing the upper and lower limits for evaluations that you have set.
This can be done using item
4
MAKE A TEST RUN.
· For more information about evaluation conditions see section 9-2 [3] Evaluation conditions.
[Information about the window settings]
· In order to set a window it is necessary to freeze the frame.
· First freeze the frame. Then operate the camera normally. Finally, freeze the frame again. The
first frozen image that was taken will be converted to binary values and this will be the final
binary image.
The second frozen image that was taken may also be converted to a binary image by repeating
steps
1
to
e
above.
[Example of recording]
Evaluation conditions
1
REGST NO.
(registration number)
2
NUMBER
(number of objects)
3
TOTAL AREA
4
MAKE A TEST RUN
5
UPPER MENU
Setting details
Enter any number from 0 to 3.
Set the range for the number of objects that will produce an OK
evaluation.
Set the range for the total area that will produce an OK evaluation.
Pressing the SET key will test the evaluation conditions, display the
test results.
This will return you to the [TYPE00-MEAS1 to 3] menu.