[2] Procedure for creating the final output conditions in a ladder circuit
A ladder circuit can be created for each object type (0 to 15) using the following procedure.
(1) Operation to invoke the [FINAL OUTPUT COND.] menu
1. Move the cursor to item
r
FINAL OUTPUT COND with the up and down keys, and press the
SET key.
-
The [RESULTS OUTPUT] menu will be displayed.
2. After moving the cursor to item
1
PAGE NO. (register number) with the up and down keys,
and pressing the SET key, specify page number "0" with the up and down keys, set the REG.
(register) item to YES with the left and right keys, and press the SET key.
-
Items
2
to
5
will be displayed.
Continued on the following page
1
[OBJECT TYPE COND]
1
OBJECT TYPE NO.
00(0~15)
2
EDIT
COPY(
←OBJ
TYPE00) INITIALIZE
3
TITLE REGISTRATION (TO NEXT SUB-MENU)
4
MEAS.0, CAMERA1
NO (TO NEXT SUB-MENU)
5
POS. ADJ.CAMERA1
NO ADJ. [REG. 0-1PNTSXY
]
6
MEAS.0, CAMERA2
NO (TO NEXT SUB-MENU)
7
POS. ADJ.CAMERA2
NO ADJ. [REG. 0-1PNTSXY
]
8
SELECT CAMERA IMG NO CAM1 CAM1 CAM1&2
0
MEASUREMENT 1
NO (TO NEXT SUB-MENU)
q
MEASUREMENT 2
NO (TO NEXT SUB-MENU)
w
MEASUREMENT 3
NO (TO NEXT SUB-MENU)
e
FINAL CALC RESULT
(TO NEXT SUB-MENU)
r
FINAL OUTPUT COND (TO NEXT SUB-MENU)
t
SYSTEM-IN/OUT
(TO NEXT SUB-MENU)
y
HALT MEAS ON NG
NO
YES
u
UPPER MENU
On the MAIN OPS MENU, move the cursor to SET-SCRN item, and press the SET key.
-
On the [SYSTEM SETUP] menu, move the cursor to item
2
OBJECT TYPE COND
and press the SET key.
2
2
[RESULTS OUTPUT]
(TYPE00)
1
PAGE.NO. (0~7) REG.NO YES
2
SET POSITION
MOVE
3
INPUT SIGNAL
AUXRLY C112(0~127) EXT-INP X0(0~6)
TMR TM0(0~7) CNT CN0(0~7)
AN00(0~15) OUT Y00(0~15)
4
LOGICAL SYMBOL
5
OUTPUT SIGNAL
OUT Y00(0~15) AUXRLY C000(0~127)
TMR TM0(0~7) SET-VL000(000~999)
CNT CN0(0~7) SET-VL000(000~999)
DEL.
6
UPPER MENU
[PAGE0]
INPUT0
LOGIC
INPUT1
LOGIC
INPUT2
LOGIC
INPUT3
LOGIC
1
0
2
3
4
5
6
7
OUT
DEL.
Row No.
Column No.
Ladder circuit
display area