3-9
3
Operation Examples (Position measurement)
1
F C1 H
[OBJECT TYPE COND]
1
OBJECT TYPE NO.
00(0~15)
2
EDIT
COPY(
←OBJ
TYPE00) INITIALIZE
3
TITLE REGISTRATION (TO NEXT SUB-MENU)
4
MEAS.0, CAMERA1
NO (TO NEXT SUB-MENU)
5
POS. ADJ.CAMERA1
NO ADJ. [REG. 0-1PNTSXY
]
6
MEAS.0, CAMERA2
NO (TO NEXT SUB-MENU)
7
POS. ADJ.CAMERA2
NO ADJ. [REG. 0-1PNTSXY
]
8
SELECT CAMERA IMG NO CAM1 CAM1 CAM1&2
0
MEASUREMENT 1
NO (TO NEXT SUB-MENU)
q
MEASUREMENT 2
NO (TO NEXT SUB-MENU)
w
MEASUREMENT 3
NO (TO NEXT SUB-MENU)
e
FINAL CALC RESULT
(TO NEXT SUB-MENU)
r
FINAL OUTPUT COND (TO NEXT SUB-MENU)
t
SYSTEM-IN/OUT
(TO NEXT SUB-MENU)
y
HALT MEAS ON NG
NO
YES
u
UPPER MENU
[
TYPE00-MEAS0
]
1
SELECT MEAS. TYPE NO MEAS-POSITION-DEVIATE
2
COPY
EXEC
←
TYPE00-CAM1NO
3
INITIALIZATION
EXEC
4
MEAS.PROG.COND
(TO NEXT SUB-MENU)
5
EVALUATION COND (TO NEXT SUB-MENU)
6
NUMERIC CALC COND (TO NEXT SUB-MENU)
7
OUTPUT CONDITIONS (TO NEXT SUB-MENU)
8
UPPER MENU
1
3
2
[
MEASURING COND
]
(TYPE00-MEAS0-POS-DEVIATION)
1
REGST NO.
0(0~7) REG.NO YES
2
SELECT MODE
1P-SCH
2P-SCH
1P-EDGE
2P-EDGE 1P-SCH
+
1P-EDGE
3
GRAY-SCALE COND (TO NEXT SUB-MENU)
4
EDGE DETECT COND (TO NEXT SUB-MENU)
5
UPPER MENU
1
2
3
1
Continued from the preceding page
(3) Operation on the [OBJECT TYPE COND] menu
1. Move the cursor to
4
MEAS.0, CAMERA1 (measurement 0 (camera 1)) and press the SET
key.
-
The [TYPE00-MEAS0] (type: 00, measurement: 0) menu will be displayed.
(4) Operation on [TYPE00-MEAS0] menu
1. Move the cursor to
1
SELECT MEAS. TYPE (selection of measurement) and press the SET
key.
2. Move the cursor to MEAS-POSITION-DEVIATE (measurement of positional deviation) and
press the SET key.
3. Move the cursor to
4
MEAS.PROG.COND (conditions of measurement program) and press
the SET key.
-
The [MEASURING COND] (measurement condition) menu will be displayed.
(5) Operation on the [MEASURING COND] menu
1. Move the cursor to
1
REGST NO. (register number) and press the SET key.
Move the cursor to YES and press the SET key.
-
Items
2
to
4
will be displayed.
2. Move the cursor to
2
SELECT MODE and press the SET key. Move the cursor to 1P-SCH (1
point search) and press the SET key.
3. Move the cursor to
3
GRAY-SCALE COND (gray scale search condition) and press the SET key.
-
The gray scale search matching setting menu, image window, and search window will be displayed.
Continued on the following page