[6] Connecting a programmable controller using the computer link function
Connect a programmable controller to the communication connector (RS232C/RS422) and the input/
output terminals on the IV-S20 main housing.
1
Connect the computer link connector (RS-232C/RS-411) of a programmable controller to the
communication connector (RS232C/RS422: 9-pin D-sub, female) on the IV-S20 main housing.
- See Chapter 14 "Computer Link" for details about the procedure for connecting to specific
manufacturers' controllers.
(The pin arrangement of the communication connector on the IV-S20 main housing is
shown on page 6-16 to 6-17.)
- In the case of RS-232C, the maximum communication cable length depends on the c o m -
munication speed.
Y0
Y1
Y2
Y3
Y4
Y5
Y6
Y7
BUSY
C(-)
X0
X1
X2
X3
X4
X5
X6
C(+)
+24V
0V
IV-S20
VIDEO CAMERA1
CAMERA2
RS232C/RS422
REMOTE
POWER
OUTPUT
INPUT
POWER
▼
▼
(side view)
Communication connector
(RS232C/RS422)
RS-232C/RS-422
Input/output terminals
1
2
(plan view)
Communication port
O/I
Programmable controller
IV-S20 main
housing
IV-S20 main
housing
2
Connect the input/output terminals of the programmable controller to the input/output terminals
on the IV-S20 main housing.
- See item [4] "Connecting to the input/output terminals (parallel I/F)" for details about wiring
procedure.
9.6, 19.2
38.4, 57.6, 115.2
15 m or less
2 to 3 m
Communication speed
Cable length
Conduct a communication test before using the devices for measurements.