9-37
Positional deviation measurement
9
Continued on the following page
· You can switch between displaying all of the headings together and displaying each one separately
by using the ESC key.
1
MEAS WINDOW(MDL0)
RECTANGLE
X-LINE
Y-LINE
2
REF IMAGE(MODEL0)
MOVE
UP.L(224,208) LO.R(287,271) REG. DISP
3
SEARCH AREA(MDL0)
MOVE UP.L(216,200) LO.R(295,279)
4
DTECT COORD(MDL0) CNTR
FREE(256,240)
5
CONTR. PIXEL(MDL0)
1
2
3
6
MEAS WINDOW(MDL1)
RECTANGLE
X-LINE
Y-LINE
7
REF IMAGE(MODEL1)
MOVE
UP.L(224,208) LO.R(287,271) REG. DISP
8
SEARCH AREA(MDL1)
MOVE UP.L(224,512)LO.R(287,512)
9
DTECT COORD(MDL1)
CNTR
FREE(256,240)
0
CONTR. PIXEL(MDL1)
1
2
3
q
DETECT ACCURANCY
STANDARD
HI-PRC
w
UPPER MENU
These items in the dotted
line are only displayed
when 2-point search is
selected.
Continued from the previous page
Specify a 1P-SCH (1-point search), a 2P-SCH (2-point search), or a 1P-SCH+1P-EDGE (1-point 1-
point edge) in item
2
SELECT MODE. Then select item
3
GRAY-SCALE COND (gray scale search
Menu
1
MEAS WINDOW(MDL0)
(measurement window)
2
REF IMAGE(MODEL0)
(reference images)
3
SEARCH AREA(MDL0)
(search area)
4
DTECT COORD(MDL0)
(detection coordinates)
5
CONTR. PIXEL(MDL0)
(pixel contraction)
6
MEAS WINDOW(MDL1)
(measurement window)
7
REF IMAGE(MODEL1)
(reference images)
8
SEARCH AREA(MDL1)
9
DTECT COORD(MDL1)
(detection coordinates)
0
CONTR. PIXEL(MDL1)
(pixel contraction)
q
DETECT ACCURACY
(accuracy of detection)
w
UPPER MENU
Setting details
Select the measurement window shape for model 0.
Record a reference image for model 0
· The upper left or lower right area of the screen specified
above will change according the setting in item
1
MEAS
WINDOW(MDL0).
Set the search area for model 0.
Set the position of the cursor inside the measurement
window for model 0.
· If FREE is selected, then the position of the cursor is
optional.
Select number of pixel contractions for model 0.
-
See page 9·6 gray scale processing using shared settings.
· When either X-LINE (horizontal line) or Y-LINE (vertical
line) are selected in item
1
MEAS WINDOW(MDL0), you
can select only 1 or 2 in item
5
.
Set these items for model 1 just the same way as item
1
to
5
above.
Set the level of detection precision for models 0 and 1.
-
See page 9·6 gray scale processing in shared settings.
This will return you to the menu [MEASURING COND]
(measurement conditions) menu.
RECTANGLE (rectangle)
X-LINE (horizontal line)
Y-LINE (vertical line)
The display in the upper left and
lower right areas of the screen.
Upper left, lower right.
Starting point, end point
The setting at
item
1