Distance and angle measurement
9-67
9
1
OBJECT :
ST-PNT
AUX
DIST
ANGLE
2
REGST NO.
00(0~15) CNTR-PNT
3
AUX. X COORD
000.0~511.0
4
AUX. Y COORD
000.0~479.0
1
OBJECT: When AUX (auxiliary) is selected
DIST-BETW-X, DIST -BETW-Y, NO may also be
displayed here.
1
OBJECT :
ST-PNT
AUX
DIST
ANGLE
2
REGST NO.
00(0~15)
DIST-BETW-2PT
3
DISTANCE
000.0~702.0 PIXEL
1
OBJECT: When DIST (distance) is selected
2PT-ANGL(HORI) (2 point horizontal),
2PT-ANGL(VERT) (2 point vertical) or NO (disabled)
may also be displayed here.
1
OBJECT :
ST-PNT
AUX
DIST
ANGLE
2
REGST NO.
00(0~15) 3PT-ANGL
3
ANGLE
-180.0~
+
180.0
゜
1
OBJECT: When ANGLE is selected
Continued from the previous page: GRAY&EDGE, GRAV.
Return to the [TYPE00-MEAS1 to 3] and select item
8
NUMERIC CAL COND
(numeric calculation condition).
[EVALUATION COND]
(TYPE00-MEAS.1-DST&ANGL MEAS)
1
OBJECT :
ST-PNT
AUX
DIST
ANGLE
2
REGST NO.
00(0~15) GRAY-SEARCH
3
X START PNT COORD 000.0~511.0
X=285.0
OK
NO
4
Y START PNT COORD 000.0~479.0
Y=250.0
OK
NO
5
DEGREE OF MATCH -10000~
+
10000
+09800
OK NO
6
MAKE A TEST RUN (SET KEY)
7
UPPER MENU
[TEST RESULT] [OUT]
Use the up and down keys to
select NO, Y0 to 7, or C000
to C127.
Alternatively, EDGE DETECT (tip
of the edge) or GRAVITY (label
center of gravity) may also be
displayed here.
- Check your selection by testing the upper and lower limits for the evaluation that you have set.
This can be done using item
6
MAKE A TEST RUN.
- For more information about evaluation conditions see section 9-2 [3] Evaluation conditions .
Continued on the following page
PERIMRTER (center of a circle), C-GRAV
(center of gravity), LEG (lines on two points),
INTRSCT-PT (crosspint over two lines) or NO
(disabled) may also be displayed here.
Evaluation conditions
1
OBJECT
2
REGST NO.
(registration number)
3
4
5
6
MAKE A TEST RUN
7
UPPER MENU
Setting details
Select the object for evaluation.
Set this at any number from 0 to 15.
Enter the ranges that will produce an OK decision.
The titles of items 3 to 5 will change, according to the settings in item
1
. The example above shows the display when
1
OBJECT: ST-PNT
(starting point) has been selected. See below for the displays when
other object settings are selected.
Pressing the SET key will test the evaluation condition, display the test
results.
This will return you to the [TYPE00-MEAS1 to 3] menu.