Other Settings and Operations
[3] Total initialization
When you newly set conditions, it is recommended that you first initialize the settings. The following
conditions should be initialized.
The total initialization function initializes all of the conditions for each object type (all object types),
input/output conditions, camera position adjustment, and display mode.
- The data stored in the flash memory and the data in the monitor display memory (RAM) are initialized
(returned to their initial state).
[Operating procedure]
1. Move the cursor to item
7
INIT ALL PARMS (initialize all parameters) with the up and down
keys, and press the SET key.
2. Press the SET key again. (Press the ESC key to abort initialization.)
-
Initialization will start, and the progress of the initialization will be displayed on the bottom
of the screen.
When initialization is complete, the message "INITIALIZING" (initializing) will change to
"INIT COMPLETE" (complete initialization).
1
[SYSTEM SETUP]
1
OPS MENU SETTING (TO NEXT SUB-MENU)
2
OBJECT TYPE COND (TO NEXT SUB-MENU)
3
I/O CONDITIONS
(TO NEXT SUB-MENU)
4
ADJ. CAM POSITION (TO NEXT SUB-MENU)
5
DISPLAY MODE
JAPANESE
ENGLISH
6
RECEIVING PARMS
EXEC
7
INIT ALL PARMS
EXEC
8
SELF DIAGNOSTICS EXEC
9
SAVE IN FLASH MEM EXEC
0
OPERATIONS
On the [MAIN OPS MENU], move the cursor to SET-SCRN, and press the SET key.
REFERENCE IMAGE
SYSTEM I/O
OBJECT TYPE DATA
■■■■■■■■
■
■■■■■■■■■■■□□□□□
INITIALIZING
See Item [8], "Initialization (edit)," in section 9-2.
- All conditions
This section
- Measurement conditions for each
measurement program number
- Measurement conditions for each
object type number