3-10
3
Operation Examples (Position measurement)
1
MEAS WINDOW(MDL0) RECTANGLE
X-LINE
Y-LINE
Image window
Search window
3
1
F C1 H
Press the TRG/BRT key on the
remote key pad, and the level
(brightness of the screen) will be
switched between H and L.
Indicates camera 1.
6
4
4
2
3
1
MES.WINDOW(MDL0) RECTANGLE
XLINE
YLINE
2
REF IMAGE(MDL0)
MOVE
UP.L(224,208) LO.R(287,271) REG. DISP
3
SEARCH AREA(MDL0) MOVE UP.L(216,200) LO.R(295,279)
4
DTECT COORD(MDL0) CNTR
FREE(256,240)
5
CONTR.PIXEL(MDL0) 1
2
3
q
DETECT ACCURANCY STANDARD
HIGH
w
UPPER MENU
Image window
Positioning mark
MOVE
The white rectangle is moved using the up, down, right or left keys (4 pixels at a time).
UP.L
The upper left corner is moved using the up, down, right or left keys (4 pixels at a time).
LO.R
The lower right corner is moved using the up, down, right or left keys (4 pixels at a time).
Continued from the preceding page
(6) Image adjustment
1. Press the SEL key.
-
The image taken by camera 1 will be displayed.
- If the image is so bright that the menu is hard to see, press the TRG/BRT key to reduce
the brightness of the image. Then, the brightness indicator in the upper right corner of
the screen will change from H to L.
2. Adjust the focus and aperture (iris) of the camera lens (see page 5·1), so that the object to be
measured is clear and easily distinguished.
3. Press the SEL key to enter the freeze image mode.
-
The indicator in the upper right corner of the screen will change from T (through) to F
(freeze).
- To store an image for the following gray scale search matching setting operations, the
screen must be in the freeze image mode. (See section 7-2 "Screen specifications" for
details about the through/freeze mode.)
(7) Operation for gray scale search matching setting
1. Press the ESC key, and all menus to be used for gray scale search matching setting will be
displayed.
- If the menu overlaps the image to be measured so that further image setting is hindered,
press the ESC key. Only item
1
will be displayed.
2. Move the cursor to
2
REF IMAGE (MDL0) (reference image) and press the SET key.
3. Surround the image to be measured with a window (solid line).
- Move the cursor to MOVE, UP.L, or LO.R and press the SET key. Then, position the window.
When the position is correct, press the SET key.
- After the image window position has been defined, move the cursor to REG. (register) with
left and right keys, and press the SET key.
- Move the cursor to DISP (display) with the left and right keys and press the SET key. Then,
the stored image will be displayed in the lower right corner of the screen. After checking the
image, press the ESC key.
Continued on the following page