9-101
Object identification (labeling) by binary conversion
9
Continued from the previous page
Continued on the following page
Menu
Setting details
1
MEAS WINDOW TYPE
(measurement window)
2
MEAS WINDOW POSIT
(position of measuring
window)
3
MASK WINDOW TYPE
4
MASK WINDOW POSIT
(mask window position)
5
THRESHOLD VALUE
6
INVERT B/W
(black and white inversion)
7
BINARY PROCESS
(binary conversion)
8
BOUDARY PROCESS
(boundary processing)
9
LABEL ORDER
0
IMAGE PRE-PROCESS
(image pre-processing)
Set the upper and lower limits for binary conversion within the range of 0 to 255.
-
See setting threshold values in shared settings on page 9·7
Set the size and position of the window in units of 1 pixel.
· If a circle or ellipse is selected in item
1
, then the two variables you need to
set are center and diameter.
Decide whether a mask window will be employed and if so which type (rectangular, round or
elliptical).
· A mask window exists inside the boundary of the measurement window and screens out
those parts of the image which are not needed in the measurement process.
Select the measurement window type: RECTANGLE (rectangular), CIRCLE (circular)
or ELLIPSE (ellipse).
Set the size and position of the mask window (which is framed with a dotted line) in units of
1 pixel.
· If a circle or ellipse was selected in item
1
, then the two variables you need to set are
center and diameter.
· It is possible to enter dimensions that make the mask window bigger than the
measurement window.
1
MEAS
WINDOW TYPE RECTANGLE
CIRCLE
ELLIPSE
2
MEAS
WINDOW POSIT MOVE
UP.L(224,208) LO.R(287,271)
3
MASK WINDOW TYPE NO
RECTANGLE
CIRCLE
ELLIPSE
4
MASK
WINDOW POSIT MOVE
UP.L(224,208) LO.R(287,271)
5
THRESHOLD VALUE U.LM
−
255
L.LM
−
100(0~255)
6
INVERT B/W
NO
YES
7
BINARY PROCESS FIXED
THRSHOLD-ADJ (VAR-DIFF VAR-RATE)
8
BOUNDARY PROCESS VALD
INVLD
9
LABEL ORDER
SACN-ORDER
SIZE
-
ORDER
0
IMAGE PRE-PROCESS OFF
SMOOTH
EDGE-EMPHASIS
ALL-EDGE
HORZ-EDGE
VERT-EDGE
q
BINARY NOIS FILTR NO
EXP.
→
CONTR.
CONTR.
→
EXP.
w
NUM. OF FILTR PASS EXPD.0(0~5) CONTR0(0~5)
e
AREA FILTER
000000PIXEL LOWER LIMIT
r
UPPER MENU
Select whether to invert the black and white in the image: YES or NO.
· NO means the white area will be measured after the image has been converted to binary
values.
· YES means the black area will be measured after the image has been converted to binary
values.
Select either fixed or threshold value correction as the binary conversion processing
method. (VAR-DIFF or VAR-RATE).
-
See methods for binary conversion in shared settings on page 9·8.
Enable or disable boundary processing.
-
See setting the window boundary in shared settings on page 9·7.
· When disabled, a workpiece contacting the window will not be measured.
Select the order for labeling objects.
-
See order of labeling in shared settings on page 9·8.
Select a method for pre-processing image data.
See pre-processing in shared settings on page 9·9.
· Item
4
will be displayed unless item
3
is set to "NO."
q
BINARY NOIS FILTR
(eliminating binary noise)
e
AREA FILTER
r
UPPER MENU
After the labeling, the area filter is a function used to identify small islands whose area is
less than a specified amount. It eliminates them from the object which is being measured.
Set the maximum number of pixels. Enter any number from 0 to 245760.
· To enter number, select
e
AREA FILTER using up and down keys, and press the SET
key twice. Select a required digit using the left and right keys, and select the required
figure using the up and down keys.
w
NUM. OF FILTR PASS
(the number of noise
elimination cycles)
Select a method for eliminating binary noise.
-
See methods for eliminating noise from binary images, expansion/contraction
and eliminating binary noise in shared settings on page 9·10.
Set the number of cycles that the binary noise elimination process will be carried
out (0 to 5). Enter number of times for expansion and contraction, separately.
This will return you to the [MEASURING COND] menu.
This is how the display looks
when item
3
MASK
WINDOW TYPE (mask
window) is set to
This is how the display looks
when item
1
MEAS WINDOW
TYPE (measurement window) is
set to RECTANGLE.