3-47
3
Operation Examples (Numeric calculation)
0
1
2
3
4
5
6
7
OUT
00N00
[PAGE0]
INPUT0
LOGIC
0
1
2
3
4
5
6
7
OUT
00N00 00N01
[PAGE0]
INPUT0
LOGIC
C000
3
2
2
3
4
5
7
8
DEL.
[OUTPUT CONDITIONS]
(TYPE00-MEAS.1-DEG OF MATCH)
1
REGIST.NO.
0(0~4) REG.NO YES
2
SET POSITION
MOVE
3
INPUT SIGNAL
REGT.NO.00(0~15)
MATCH M0(0~1) CRD-X0(0~1) CRD-Y0(0~1)
LVL 0(0~1)
CAL N00(0~15) AUXRLY C000(0~127)
4
LOGICAL SYMBOL
5
OUTPUT SIGNAL
AUX.RLYC000(0~127) DEL.
6
UPPER MENU
[PAGE 0]
INPUT0
LOGIC
INPUT1
LOGIC
INPUT2
LOGIC
INPUT3
LOGIC
1
0
2
3
4
5
6
7
OUT
Column No.
00N00
0
1
2
3
4
5
6
7
OUT
00N01
[PAGE0]
INPUT0
LOGIC
Continued from the preceding page
(3) Operation on the [OUTPUT CONDITIONS] menu
1. On the [TYPE00-MEAS1] menu, move the cursor to
9
OUTPUT CONDITIONS (output
conditions) with the up and down keys, and press the SET key.
-
The [OUTPUT CONDITIONS] menu will be displayed.
2. Move the cursor to
1
REGIST.NO. (register number) with the up and down keys, and press
the SET key. Move the cursor to "YES" with the left and right keys, and press the SET key.
-
Items
2
to
6
will be displayed.
3. Move the cursor to
2
SET POSITION with the up and down keys, and press the SET key.
- Move the cursor to the 0th column of INPUT 0 for logic setting using the up, down, left and
right keys, and press the SET key.
4. Move the cursor to
3
INPUT SIGNAL with the up and down keys, and press the SET key.
- Move the cursor to CAL N00 (0 to 15) with the left and right keys, enter CAL N00 with the up
and down keys, and press the SET key.
5. Move the cursor to
4
LOGICAL SYMBOL with the up and down keys, and press the SET
key.
- Move the cursor to "-||-" and press the SET key.
-
The logical condition will be displayed in the 0th column of INPUT 0.
- 00N00 means the results of the calculation N00, entered on the [NUMERIC CALC] menu,
for registration No.00.
6. Move the cursor to
2
SET POSITION (setting position) with the up and down keys, and
press the SET key. Move the cursor to the 1st column of INPUT 0 for logic setting using the
left and right keys, and press the SET key.
· Enter CAL. N01 as an input signal, as described in steps 4 and 5.
7. Move the cursor to
5
OUTPUT SIGNAL with the up and down keys, and press the SET key.
- Specify C000 for the auxiliary relay number with the up and down keys, and press the SET
key.
-
The output coil for INPUT 0 will be displayed.
8. Move the cursor to
6
UPPER MENU with the up and down keys, and press the SET key.
-
The screen will return to the [OBJECT TYPE COND] (conditions of object type) menu.
Continued on the following page