8
Parameters
Overview of parameters
Operating Instructions – Compact Extra-Low Voltage Drives
60
No. Parameters
Unit
Factory set-
ting
Min.
Max.
Class
Explanation
0x41 Coasting, CW
Revolu-
tions
0
-32768 32767 System
0x42 Coasting, CCW
1/65535
revolutions
0
0
65535 System
0x43 Coasting, CCW
Revolu-
tions
0
-32768 32767 System
0x44 Position1/distance 1/66535
revolutions
0
0
65535 Application
P1 –
65535/360 * de-
grees
0x45 Position1/distance Revolu-
tions
0
-32768 32767 Application
P1 – number of re-
volutions
0x46 Position window
positive
1/65535
revolutions
1000
0
65535 System
Position window for
message
0x47 Position window
positive
Revolu-
tions
0
-32768 32767 System
Position window for
message
0x48 Position window
negative
1/65535
revolutions
1000
0
65535 System
Position window for
message
0x49 Position window
negative
Revolu-
tions
0
-32768 32767 System
Position window for
message
0x4A U
DC48V
overvoltage
threshold
mV
58000
0
65535 System
Overvoltage > 58 V
0x4B U
DC48V
under-
voltage threshold
mV
18000
0
65535 System
Undervoltage < 18 V
0x4C U
DC48V
voltage hys-
teresis
mV
2000
0
65535 System
Hysteresis for
voltage signal
0x4D Ballast chopper
switch-on
threshold
mV
54000
0
65535 System
Brake chopper
switch-on threshold
0x4E Ballast chopper
switch-off
threshold
mV
52000
0
65535 System
Brake chopper
switch-off threshold
0x4F Temperature sig-
nal threshold
°C
100
0
110
System
Overtemperature >
100°C
0x50 Temperature sig-
nal delta hyster-
esis
°C
5
0
110
System
Hysteresis for tem-
perature signal
0x51 Gear unit ratio
1
1
65535 System
Has no effect on the
motor
0x52 RS485 address
1
1
127
Application
Address of engi-
neering interface
0x53 Position 2
1/65535
revolutions
0
0
65535 Application
P2 –
65535/360 * de-
grees
0x54 Position 2
Revolu-
tions
1
-32768 32767 Application
P2 – number of re-
volutions
26718014/EN – 11/2020