8
Parameters
Overview of parameters
Operating Instructions – Compact Extra-Low Voltage Drives
61
No. Parameters
Unit
Factory set-
ting
Min.
Max.
Class
Explanation
0x55 Position 3
1/65535
revolutions
0
0
65535 Application
P3 –
65535/360 * de-
grees
0x56 Position 3
Revolu-
tions
2
-32768 32767 Application
P3 – number of re-
volutions
0x57 Position 4
1/65535
revolutions
0
0
65535 Application
P4 –
65535/360 * de-
grees
0x58 Position 4
Revolu-
tions
3
-32768 32767 Application
P4 – number of re-
volutions
0x59 Homing speed
min
-1
1000
0
65535 Application
Speed for reference
travel
0x5A Homing current
mA
Depending
on motor
type
0
4500
Application
DCA63S: 8000
DCA63M: 10500
DCA63L: 18000
0x5B Homing offset
1/65535
revolutions
0
0
65535 System
Offset for 0-position
– rev. component
0x5C Homing offset
Revolu-
tions
0
-32768 32767 System
Offset for 0-position
– revolutions
26718014/EN – 11/2020