8
Parameters
Overview of parameters
Operating Instructions – Compact Extra-Low Voltage Drives
58
No. Parameters
Unit
Factory set-
ting
Min.
Max.
Class
Explanation
0xF FE_Speed_Y1
min
-1
500
-30000 29999 System
Speed A1/N4
0x10 FE_Speed_Y2
min
-1
500
-30000 29999 System
Speed A1/N4
0x11 FE_Speed_Y3
min
-1
500
-30000 29999 System
Speed A1/N4
0x12 FE_Speed_Y4
min
-1
500
-30000 29999 System
Speed A1/N4
0x13 Speed_X1_Hyst
Digits
0
0
1023
System
0x14 Speed_X2_Hyst
Digits
0
0
1023
System
0x15 Speed_X3_Hyst
Digits
0
0
1023
System
0x16 Speed fault
min
-1
0
0
29999 System
0x17 Fixed speed N1
min
-1
1000
0
29999 Application
Fixed speed N1
0x18 Fixed speed N2
min
-1
2000
0
29999 Application
Fixed speed N2
0x19 Fixed speed N3
min
-1
4000
0
29999 Application
Fixed speed N3
-
Fixed speed N4
min
-1
500
0
29999 Application
Fixed speed N4
0x1A t-up clockwise
ms for
1000 min
-1
100
0
65535 Application
Ramp up/1000 min
-1
0x1B t-down clockwise
ms for
1000 min
-1
100
0
65535 Application
Ramp
down/1000 min
-1
0x1C t-up counterclock-
wise
ms for
1000 min
-1
100
0
65535 Application
Ramp up/1000 min
-1
0x1D t-down counter-
clockwise
ms for
1000 min
-1
100
0
65535 Application
Ramp
down/1000 min
-1
0x1E Speed controller
KP
Depending
on motor
type
0
65535 Application
DCA63S: 120
DCA63M: 168
DCA63L: 160
0x1F Speed controller KI
128
0
65535 Application
Speed controller I
gain
0x20 Speed controller
KD (reserved)
0
0
65535
No function
0x21 K_ff
1
0
65535 System
0x22 Actual speed aver-
aging
2
x
ms
1
0
15
System
0x23 Resolution of ac-
tual outputs
Pulse/
mech. rev-
olution
6
0
100
System
0x24 Speed signal
threshold
min
-1
0
0
29999 System
0x25 Speed signal delta
hysteresis
min
-1
0
0
29999 System
0x26 FE_Current_X1
Digits
0
0
1023
System
0x27 FE_Current_X2
Digits
1023
0
1023
System
0x28 FE_Current_X3
Digits
1023
0
1023
System
26718014/EN – 11/2020