12
Project planning
Operation with reduced supply voltage
Operating Instructions – Compact Extra-Low Voltage Drives
85
12.5.2
Operating data with reduced supply voltage, e.g. DC 24 V
The following table shows the operating data with reduced supply voltage. Values that
differ from the standard values have a gray background.
Type
DCA63S-048P00/
DBC00
DCA63M-048P00/
DBC00
DCA63L-048P00/
DBC00
Nominal torque
M
N
0.45 Nm
0.65 Nm
0.85 Nm
Maximum motor torque
M
MotMax
0
1.89 Nm
3.00 Nm
2.55 Nm
Maximum motor torque at
1500 min
-1
M
MotMax
1500 0.95 Nm
1.80 Nm
2.20 Nm
Maximum motor torque at
2000 min
-1
M
MotMax
2000 0.60 Nm
1.00 Nm
1.50 Nm
Maximum motor speed
n
no-load operation
3000 min
-1
2500 min
-1
2600 min
-1
Operating speed
n
red
2000 min
-1
Motor power
P
red
94 W
136 W
178 W
Supply
U
red
Reduced load voltage DC 24 V
1)
Nominal current
I
N
5.4 A
6.6 A
8.6 A
No-load current @ n
N
I
L
0.5 A
0.5 A
0.6 A
1) The UL approval applies only to operation with nominal voltage.
1000
2000
3000
4000
5000
[1]
M
MotMax 1500
M
MotMax 2000
Mn
M
MotMax
0
M/Nm
n/min
-1
[2]
31494574731
[1] Operating point
[2] Maximum motor speed
26718014/EN – 11/2020