8
Parameters
Parameter description
Operating Instructions – Compact Extra-Low Voltage Drives
64
INFORMATION
Make sure that always one digital output is set to "Ready".
0x6 – Restart
The "Restart" parameter is used to configure the behavior after critical faults. It is not
possible to operate the drive while critical faults are present. If there are no longer any
faults, the drive can be switched to "ready" automatically or manually via an acknowl-
edgment.
0 = Automatic restart
1 = Acknowledgment required (factory setting)
0x17 – Fixed speed N1
The parameter value N1 determines the motor setpoint speed in revolutions per
minute depending on the selected operating mode and with corresponding activation
by digital inputs IN 1 and IN 2.
0x18 – Fixed speed N2
The parameter value N2 determines the motor setpoint speed in revolutions per
minute depending on the selected operating mode and with corresponding activation
by digital inputs IN 1 and IN 2.
0x19 – Fixed speed N3
The parameter value N3 determines the motor setpoint speed in revolutions per
minute depending on the selected operating mode and with corresponding activation
by digital inputs IN 1 and IN 2.
- – Fixed speed N4
The following functions are available in parameter value N4:
• N4 = 0: Analog input is enabled. Depending on the selected operating mode and
with corresponding activation by digital inputs
IN
1 and
IN
2, the speed reference
is used as analog input signal 0-10 V at PIN 8.
Information:
The scaling and the profile of the input function are set in parameters X1 to X3 and
Y0 to Y4. For detailed information, see chapter "Parameterizing the analog set-
• N4 > 0: Fixed speed N4 is used. The entered parameter value determines the mo-
tor speed in revolutions per minute depending on the selected operating mode and
with corresponding activation by digital inputs IN 1 and IN 2.
0x1A – t-up clockwise
The parameter is used as the ramp slope (gradient) for the acceleration process in
clockwise rotation. The time specified here is to be implemented for a setpoint jump of
1000
min
-1
. This means the drive follows the setpoint ramp by
1000
revolutions in the
time set here.
0x1B – t-down clockwise
The parameter is used as the ramp slope (gradient) for the deceleration process in
clockwise rotation. The time specified here is to be implemented for a setpoint jump of
1000
min
-1
. This means the drive follows the setpoint ramp by
1000
revolutions in the
time set here.
0x1C – t-up counterclockwise
26718014/EN – 11/2020