Parameters
Parameter description
Operating Instructions – Compact Extra-Low Voltage Drives
63
8.2
Parameter description
This chapter contains additional information about the application-specific parameter
settings. These are used to adapt to the case of application. Set these parameters
during startup.
System-specific parameters are not described here as they are saved in the factory
settings. Only change these parameters after consultation with SEW-EURODRIVE.
0x3 – OUT 1
Specifies the function for digital output OUT 1. The following options are available:
• 1: Reserved
• 2: Reserved
•
3: Speed signal: Speed ≥ P0x24 (speed signal threshold)
•
4: Current signal: Motor current ≥ P0x32 (current signal threshold)
• 5: Ready signal
• 6: Position window reached
• 7: Temperature signal
• 8: RS485 controlled
• 9: Internal brake control (factory setting)
INFORMATION
With brakemotors, the function of digital output
OUT
1 cannot be assigned freely as
this output is permanently assigned the function of controlling the holding brake.
0x4 – OUT 2
The parameter defines which status output is issued at output D02. The following op-
tions are available:
• 1: Reserved
•
2: Increments_1: Revolution counter. Default resolution = 6 pulses/rev.
•
3: Speed signal: Speed ≥ P0x24 (speed signal threshold)
•
4: Current signal: Motor current ≥ P0x32 (current signal threshold)
• 5: Ready signal
• 6: Position window reached (factory setting)
• 7: Temperature signal
• 8: RS485 controlled
0x5 – OUT 3
Specifies the function for digital output OUT 3. The following options are available:
• 1: Reserved
•
2: Increments_2: Revolution counter. Default resolution = 6 pulses/rev.
•
3: Speed signal: Speed ≥ P0x24 (speed signal threshold)
•
4: Current signal: Motor current ≥ P0x32 (current signal threshold)
• 5: Ready signal (factory setting)
• 6: Position window reached
• 7: Temperature signal
• 8: RS485 controlled