2
Safety notes
Electrical installation
Operating Instructions – Compact Extra-Low Voltage Drives
10
2.7
Electrical installation
Ensure that all of the required covers are correctly attached after carrying out the elec-
trical installation.
Make sure that preventive measures and protection devices comply with the applica-
ble regulations (e.g. EN 60204-1 or EN 61800-5-1).
2.8
Protective separation
The product meets all requirements for protective separation of power and electronics
connections in accordance with
EN
61800-5-1. The connected signal circuits must
meet requirements according to SELV (
S
afety
E
xtra
L
ow
V
oltage) or PELV (
P
rotective
E
xtra
L
ow
V
oltage) to ensure protective separation. The installation must meet the re-
quirements for protective separation.
2.9
Startup/operation
Observe the safety notes in the chapters Startup and Operation in the documentation.
Ensure that all required covers are mounted properly before applying the supply
voltage.
Depending on the degree of protection, products may have live, uninsulated, and
sometimes moving or rotating parts as well as hot surfaces during operation.
In the event of deviations from normal operation, switch the product off. Possible devi-
ations are increased temperatures, noise, or vibration, for example. Determine the
cause. Contact
SEW‑EURODRIVE
if necessary.
Mechanical blocking or internal protective functions of the product can cause a motor
standstill. Eliminating the cause of the problem or performing a reset may result in the
drive restarting automatically. If, for safety reasons, this is not permitted for the drive-
controlled machine, first disconnect the product from the supply system and then start
troubleshooting.
Risk of burns: The surface temperature of the product can exceed
60
°C during opera-
tion. Do not touch the product during operation. Let the product cool down before
touching it.
26718014/EN – 11/2020