8
Parameters
Overview of parameters
Operating Instructions – Compact Extra-Low Voltage Drives
59
No. Parameters
Unit
Factory set-
ting
Min.
Max.
Class
Explanation
0x29 FE_Current_Y0
%
0
0
100
System
0x2A FE_Current_Y1
%
0
0
100
System
0x2B FE_Current_Y2
%
100
0
100
System
0x2C FE_Current_Y3
%
100
0
100
System
0x2D FE_Current_Y4
%
100
0
100
System
0x2E Current_X1_Hyst
Digits
0
0
1023
System
0x2F Current_X2_Hyst
Digits
0
0
1023
System
0x30 Current_X3_Hyst
Digits
0
0
1023
System
0x31 Current fault
%
0
0
100
System
0x32 Current signal
threshold
mA
Depending
on motor
type
0
32767 System
DCA63S: 8000
DCA63M: 10500
DCA63L: 18000
0x33 Current signal
delta hysteresis
mA
0
0
65535 System
0x34 Current time con-
stant
ms
1
1
5000
System
0x35 Current gating time ms
0
0
5000
System
0x36 Reversing
threshold
min
-1
10000
0
29999 System
0x37 Reversing
threshold delta
hysteresis
min
-1
50
0
29999 System
P54
0x38 I_Max_driv-
ing_clockwise
mA
Depending
on motor
type
0
65535 System
DCA63S: 16000
DCA63M: 21000
DCA63L: 36000
0x39 I_Max_driv-
ing_counterclock-
wise
mA
0
65535 System
0x3A I_Max_bra-
king_clockwise
mA
0
65535 System
0x3B I_Max_bra-
king_counterclock-
wise
mA
0
65535 System
0x3C Hold gain KP_H
1
0
65535 Application
Hold controller pro-
portional gain
0x3D PWM/freq: Lower
base frequency
Hz
25
25
15000 System
0x3E PWM/freq: Upper
base frequency
Hz
15000
25
15000 System
0x3F Max. positioning
speed
min
-1
4000
0
29999 Application
Max. speed for posi-
tioning mode
0x40 Coasting, CW
1/65535
revolutions
0
0
65535 System
26718014/EN – 11/2020