7
DCAShell engineering software
Status and diagnostics
Operating Instructions – Compact Extra-Low Voltage Drives
52
7.2
Status and diagnostics
This area has the following functions:
• Display current drive status [6].
• Display fault memory [7]. The last 3 errors are displayed in the fault memory. Also
refer to chapter "
73) in this regard.
• Under the "Monitor" tab [4], you can record the values selected on the left-hand
side [3] as a function of time. If you are working with a smaller screen, you will
need to drag the window to make it larger. To do so, press and hold the left mouse
button on the edge of the window and drag it upwards.
• The "Output window" tab displays information regarding the communication status.
[5]
[6]
[7]
[1]
[2]
[3]
[4]
28545540747
[1] Device information, "Motor stop" button
[2] Connection state
[3] Actual values; for a description see chapter "
57).
[4] Monitor, displays the selected values as a function of time
[5] Change language
[6] Drive status, shows if the motor is ready to start
[7] Fault memory, displays the last 3 faults
26718014/EN – 11/2020