6
Startup
Parameter description
Operating Instructions – CMP ELVCD
59
6.8
Parameter description
6.8.1
Display values
Parameter 001.0
Actual speed (signed)
The parameter indicates the actual speed of the motor that the inverter calculates
based on the encoder signals.
Parameter 002.0
Actual velocity
The parameter indicates the speed of the drive.
Parameter 003.0
Actual position
The parameter indicates the signed position of the drive in encoder increments.
Parameter 004.0
Actual position
The parameter indicates the signed position of the drive in user units.
Parameter 005.0
Active current
Range of values 0 – 400% of nominal motor current
The parameter indicates the current active current of the drive.
Parameter 006.0
Motor utilization
The parameter indicates the capacity utilization of the motor in % which has been de-
termined using a motor temperature model.
Parameter 007.0
Device utilization
The parameter indicates the capacity utilization of the inverter in %.
Parameter 008.0
DC link voltage
The parameter indicates the voltage in %, measured in the DC link of the inverter.
Parameter 009.0
Motor temperature
The parameter indicates the temperature of the motor in °C.
Parameter 009.1
Power section temperature
22759468/EN – 11/2017