6
Startup
Parameter description
Operating Instructions – CMP ELVCD
61
Parameter 025.0
Input STO 1
The parameter indicates the state of the digital input STO 1.
Parameter 026.0
Input STO 2
The parameter indicates the state of the digital input STO 2.
Parameter 030.0
Limit switch type
The parameter indicates the limit switch type (NC or NO contact).
The limit switch type is configured in MultiMotion.
Parameter 030.0 – 036.0
Digital input DI00 – DI06
The parameters have no function for the ELVCD drive. The DriveManager displays the
statuses of the digital inputs.
Parameter 037.0
Digital input DI07 (limit switch CCW/negative)
The parameter indicates the state of the digital input DI07 (limit switch CCW/negative).
Parameter 038.0
Digital input DI08 (limit switch CW/positive)
The parameter indicates the state of the digital input DI08 (limit switch CW/positive).
Parameter 039.0
Digital input DI09 (controller enable)
The parameter indicates the state of the digital input DI09 (controller enable). The
parameter indicates whether the inverter is enabled.
Parameter 050.0
Digital output DO00 (ready for operation)
The parameter indicates the state of the digital output DO00 (ready for operation). The
parameter indicates whether the drive is ready for operation.
Parameter 051.0
Digital output DO01
The parameter indicates the state of the digital output DO01. The parameter indicates
whether the function set in parameter
P620.0
is active.
Parameter 052.0
Digital output DO02
22759468/EN – 11/2017