5
Electrical installation
Installation topology (example)
Operating Instructions – CMP ELVCD
25
5.4.1
Switching example with digital inputs and limit switches
The following figure shows a switching example with digital inputs DI07 and DI08 for
reading out limit switches:
[3]
[2]
[1]
ELVCD
MOVI-PLC
®
C
AN
DHP11B
X30
2
2
2
2
0
1
2
18077064075
[1]
Supply of ELVCD drive
[2]
Limit switch CW/positive
[3]
Limit switch CCW/negative
The ELVCD drive can evaluate 9 digital inputs (2 of which are for limit switches) and
forward these signals to the higher-level controller via the CAN bus.
5.4.2
Switching example with digital outputs
The following figure shows a switching example with digital outputs DO01 and DO02:
[3]
[2]
[1]
ELVCD
MOVI-PLC
®
C
AN
DHP11B
X30
2
2
2
2
0
1
2
18077066763
[1]
Supply of ELVCD drive
[2]
Relay
[3]
Signal lamp
The ELVCD drive has 2 parameterizable digital outputs. These can be set using the
ELVCD DriveManager.
22759468/EN – 11/2017