10
Technical data
Characteristic curves
Operating Instructions – CMP ELVCD
99
10.5.5
Dynamic characteristic curve, CMP50M ELVCD and CMP50M ELVCD-EC
M
/
N
m
0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
4.5
5.0
0
500
1000
1500
2000
2500
3000
3500
n / min
-1
18014411016819723
10.5.6
Thermal capacity utilization
The following table shows the possible thermal capacity utilization of the drive in S1
motoring operation at 40 °C:
Motor
type
Drive design
Chopper power
loss
Nominal motor torque
P
V
M
N
at
3000 min
-1
at
1500 min
-1
at
200 min
-1
CMP50S
Mounted on
inverter
0 W
0.75 Nm
0.80 Nm
0.80 Nm
7.5 W
0.63 Nm
0.70 Nm
0.70 Nm
15 W
0.63 Nm
0.45 Nm
0.45 Nm
Mounting
close to the
motor
0 W
0.95 Nm
1.05 Nm
1.05 Nm
7.5 W
0.95 Nm
1.00 Nm
1.00 Nm
15 W
0.95 Nm
1.00 Nm
1.00 Nm
CMP50M
Mounted on
inverter
0 W
1.05 Nm
1.10 Nm
1.15 Nm
7.5 W
0.88 Nm
0.99 Nm
1.01 Nm
15 W
0.50 Nm
0.71 Nm
0.74 Nm
Mounting
close to the
motor
0 W
1.50 Nm
1.50 Nm
1.50 Nm
7.5 W
1.30 Nm
1.40 Nm
1.40 Nm
15 W
1.1 Nm
1.2 Nm
1.2 Nm
10.5.7
Thermal characteristic curves
The following diagrams show the possible thermal capacity utilization of the drives in
operation with regenerative sequences. If an external brake chopper and braking res-
istor are used, the chopper power loss can be reduced to 0 W (→
26).
22759468/EN – 11/2017