10
Technical data
CAN connection cables
Operating Instructions – CMP ELVCD
103
CMP50S, CMP50M with brake BK02
Permitted braking work per hour
W
2
3.5 kJ
Permitted total braking work (braking work until maintenance)
W
insp
0.350 × 10³ kJ
Power consumption of the coil
P
6.7 W
Brake response time
t
1
80 ms
Brake application time
t
2
20 ms
INFORMATION
The response and application times are guide values that were determined at maxi-
mum braking torque.
Possible response times of switching elements or controllers were not taken into ac-
count.
INFORMATION
If the permitted braking work per braking W
1
is exceeded during braking or if the per-
mitted total braking work W
insp
is reached, it can no longer be guaranteed that the
brake will be applied.
In this case, the drive does not brake.
10.7
CAN connection cables
When individual CAN connection cables are used, SEW‑EURODRIVE recommends
the cable type "Belden 9841/LOW-capacitance computer cable for EIA".
10.7.1
Description
24 AWG stranded TC wire, insulated with polyethylene, drilled, shielded with Beldfoil
®
(100%) + TC braid (90% shielding), 24 AWG stranded TC drain wire, PVC sheath.
10.7.2
Physical properties (in total)
Conductor:
AWG
Twisted-pairs
AWG
Stranding
Conductor mater-
ial
1
24
7x32
TC – tinned copper
10.7.3
Mechanical properties (in total)
Mechanical properties (in total)
Operating temperature
-30 °C to +80 °C
Nominal UL operating temperature
80 °C
Weight of raw cable
36 lbs/1000 ft.
Max. recommended tensile stress
72.3 lbs.
22759468/EN – 11/2017