6
Startup
Parameter description
Operating Instructions – CMP ELVCD
66
The parameter indicates whether the reference travel has not been completed suc-
cessfully. Check the configuration.
Parameter 082.3
Signal: Motor and angular encoder identification
The parameter indicates whether the encoder identification is not correct. Check the
encoder configuration.
Parameter 082.4
Signal: Travel program: unknown fault
Contact SEW‑EURODRIVE Service.
Parameter 082.5
Signal: Travel program: invalid jump destination
Contact SEW‑EURODRIVE Service.
Parameter 082.6
Signal: CAN communication error
The parameter indicates whether the CAN bus communication failed. Check whether
CAN bus addresses have been assigned twice.
Parameter 082.7
Signal: RS232 communication error
The parameter indicates whether the serial communication is faulty. Check the dia-
gnostics cable.
Parameter 082.8
Signal: Position data set fault
Contact SEW‑EURODRIVE Service.
Parameter 082.9
Signal: Faulty operating mode change
The parameter indicates whether the output stage was switched on during operating
mode change.
Parameter 083.0
Signal: Fault during positioning precalculation
Contact SEW‑EURODRIVE Service.
Parameter 083.1
Signal: Stack overflow
Contact SEW‑EURODRIVE Service.
Parameter 083.2
Signal: Checksum error
22759468/EN – 11/2017