4.1
Installation notes
INFORMATION
Adhere to the safety notes during installation.
WARNING
Improper installation of ELVCD drive or mount-on components.
Risk of injury.
•
Adhere to the notes on installation.
•
Before releasing shaft connections, make sure that there are no active torsional
moments present (tensions within the system).
WARNING
Risk of injury if the ELVCD drive starts up unintentionally.
Severe or fatal injuries.
•
Secure the output shaft against rotation.
4.2
Required tools and resources
•
Set of wrenches
•
Torque wrench
•
Mounting device
•
Compensation elements (shims and spacing rings), if necessary
•
Fasteners for output elements
•
Lubricant (e.g. NOCO
®
fluid)
•
Standard parts are not included in the delivery
4.3
Installation tolerances for motor shaft ends
The following tables shows the permitted tolerances of the shaft ends and flanges of
the ELVCD drive.
Shaft end
Flanges
Diameter tolerance according to EN 50347
•
ISO k6
•
Center hole in accordance with DIN 332,
shape DR..
Centering shoulder tolerance in ac-
cordance with EN 50347
•
ISO j6