7
Operation
ELVCD DriveManager
Operating Instructions – CMP ELVCD
74
[B] Single axes area
The edit boxes, buttons and status messages in this area are assigned to the respect-
ive axis. The ELVCD DriveManager only lists the axes configured in MultiMotion or in
the Application Configurator.
[1] [SBUS] button
The "SBUS" button assigns SBus addresses to the axes on the basis of their ID num-
ber.
[2] [Manual mode] button
Use this button to switch to manual mode.
[3] "Inverter fault" status display
Red: There is a fault in the inverter. To display the fault code and other information,
move the mouse pointer over the fault display. An overview of the fault codes can be
found in section "Fault list" (→
85).
Gray: There is no fault.
[4] "Axis-Connected" status display
Green: The drives communicate with the controller via the SBus. Initialization can take
several seconds after starting the controller.
Gray: No communication via the SBus takes place.
[5] "Backed-up parameters" status display
Green: The parameter set of the ELVCD drives can be found in the folder "User Data"
of the current project in MOVITOOLS
®
MotionStudio.
Gray: No parameter set present.
[6] "IP address" display
Display of IP address of controller in MOVITOOLS
®
MotionStudio.
[7] "Fault in program module" status display
Red: Fault in the processing of a program module. To display the fault code and other
information, move the mouse pointer over the fault display. An overview of the fault
codes can be found in section "Fault list" (→
Gray: There is no fault.
[8] [Reset] button
DANGER!
Automatic start-up of the ELVCD drive after acknowledging an active
fault. Severe or fatal injuries.
Ensure that an automatic start-up is not a danger to people and equipment.
All active faults with the exception of certain STO fault messages are acknowledged
by pressing this button. These can only be acknowledged by restarting the drive. If the
enable and setpoints ≠ 0 are still present after acknowledging the fault, the drive at-
tempts to follow the setpoint.
[9] [Open parameter tree] button
Use this button to switch to the parameter tree display. Access to the parameters is
possible during operation of the ELVCD drives, and changes become effective imme-
diately.
22759468/EN – 11/2017