10
Technical data
CAN connection cables
Operating Instructions – CMP ELVCD
104
Mechanical properties (in total)
Min. bending radius of secondary axis
2.5 inch
Applicable specifications and compliance with regulatory specifications (total)
Applicable standards
NEC/(UL) specification
CM
CEC/C(UL) specification
CM
AWM specification
UL style 2919 (30 V 80°)
EU CE mark (Y/N)
Yes
EU RoHS compliant (Y/N)
Yes
EU RoHS compliance date (MM/DD/YYYY)
01/01/2004
Plenum / Non-Plenum:
Plenum (Y/N)
No
Plenum number
82841, 89841
10.7.4
Electrical properties (in total)
Electrical properties (in total)
Characteristic rated impedance
Impedance (ohms)
120
Nominal capacitance conductor/conductor
Capacitance (pF/ft)
12.8
Nominal capacitance conductor/other conductor &
shield
Capacitance (pF/ft)
23.0
Nominal propagation speed
VP (%)
66
Nominal delay time
Delay (ns/ft)
1.6
Nominal value of the direct current resistance of the
conductor
Nominal DC resistance at 20 °C (ohm/1000 ft)
24.0
Nominal value of the direct current resistance of the
outer shield
Nominal DC resistance at 20 °C (ohm/1000 ft)
3.4
Nominal attenuation
Attenuation (dB/100ft)
0.6 (at 1 MHz)
Max. operating voltage – UL
Voltage
300 V RMS
20 V RMS (UL AWM Style
2919)
22759468/EN – 11/2017