11 Fault and protection parameters
indicates that the parameters can be set during operation.
Parame
ter
Parameter function
Setting range
Factory
setting
11-14
First failure type
0:No fault
1:Short circuit protection (sc)
2:Overcurrent during acceleration (oc1)
3:Overcurrent during deceleration (oc2)
4:Overcurrent at constant speed (oc3)
5:Overvoltage during acceleration (ou1)
6:Overvoltage during deceleration (ou2)
7:Overvoltage at constant speed (ou3)
8:Reserved
9:Undervoltage (UV)
10:Inverter overload (OL2)
11:Motor overload (ORL1)
12:Input phase loss (SPI)
13:Output phase loss (SPO)
14:Module overheat (oh2)
15:External fault (EF)
16:Communication error (CE)
17:Contactor fault (Cotr)
18:Current detection fault (it)
19:Motor auto-tuning fault (TE)
20:Reserved
21:EEPROM read write error (EEP)
22:Inverter hardware fault (EIU)
23:Motor short circuit to ground (SG)
24:Reserved
25:Reserved
26:Running time arrival(Eond)
27:Reserved
28:Reserved
29:Power-on time arrival(EIND)
30:
Load failure (oLL)
31:The PID feedback disconnected (PIDE)
40:
Wave-by-wave current limiting fault
(CbC)
-
11-15
Second failure type
-
11-16
Third (last) fault type
-
11-17
Frequency at the third (latest) failure
-
-
11-18
Current at the third (latest) fault
-
-
11-19
Bus voltage at the third (latest) fault
-
-
11-20
Input terminal status at the third
(latest) fault
-
-
11-21
Output terminal status at the third
(latest) fault
-
-
Summary of Contents for S3100A Series
Page 1: ...S3100Aseries inverter General Open loop Vector Control IM User manual User Manual ...
Page 24: ...20 Size 5 Unit mm S3100A 4T45G 55P 4T110G Size 6 Unit mm S3100A 4T110G 132P 4T160G 185P ...
Page 25: ...21 Size 7 Unit mm S3100A 4T185G 200P 4T220G Size 8 Unit mm S3100A 4T220G 250P 4T315G ...
Page 26: ...22 Size 9 Unit mm S3100A 4T315G 355P 4T400G 450P Size 10 Unit mm S3100A 4T450G 500P 4T500G ...