133
Function
description
Address
definition
Description of data meaning
R/W
characteristic
Analog AFM
output control
2002H
0
~
7FFFmeans 0%
~
100%
W/R
Pulse DFM (P)
output control
2004H
0
~
7FFFmeans 0%
~
100%
W/R
Address
description of
start/stop
parameters
3000H
Running frequency
R
3001H
Setting frequency
R
3002H
Bus voltage
R
3003H
Output voltage
R
3004H
Output current
R
3005H
Operation rotating speed
R
3006H
Output power
R
3007H
Output torque
R
3008H
PID set value
R
3009H
PID feedback value
R
300AH
Terminal input flag state
R
300BH
Terminal output flag state
R
300CH
Analog quantity AVI1 value
R
300DH
Analog quantity AVI2/ACI value
R
300EH
Reserved
R
300FH
Count value
R
3010H
Length
R
3011H
Load speed
R
3012H
Multi-speed and the current number of PLC
R
3013H
PULSE input pulse frequency(unit: 1Hz)
R
3014H
Communication setting value
R
3015H
Reserved
R
3016H
Main frequency X display
R
3017H
Auxiliary frequency Y display
R
Inverter fault
address
5000H
Fault information code coincides with number of fault type in
function code menu. But the data here returned to the host is in
hexadecimal system and not fault character.
R
Summary of Contents for S3100A Series
Page 1: ...S3100Aseries inverter General Open loop Vector Control IM User manual User Manual ...
Page 24: ...20 Size 5 Unit mm S3100A 4T45G 55P 4T110G Size 6 Unit mm S3100A 4T110G 132P 4T160G 185P ...
Page 25: ...21 Size 7 Unit mm S3100A 4T185G 200P 4T220G Size 8 Unit mm S3100A 4T220G 250P 4T315G ...
Page 26: ...22 Size 9 Unit mm S3100A 4T315G 355P 4T400G 450P Size 10 Unit mm S3100A 4T450G 500P 4T500G ...