100
Output frequency
Hz
Time
Set frequency
f
T
Rated frequency
f
b
Figure 5-14 S curve acceleration and deceleration B
07-14
Rotation speed tracking mode
Factory setting
0
Setting range
0
Start from stop frequency
1
Start from zero speed
2
Start from maximum frequency
In order to complete the speed tracking process in the shortest time, choose the method of inverter tracking:
0: Track down from the frequency of power failure, this method is usually selected.
1: Start tracking from 0 frequency and use when the power is off for a long time before restarting.
2: Track down from the maximum frequency, generally used for generating loads.
07-15
Rotation speed tracking speed
Factory setting
20
Setting range 1
~
100
When the speed tracking is restarted, select the speed of the speed tracking.
The larger the parameter, the faster the tracking speed.However, if the setting is too large, the tracking effect may
be unreliable.
08 Man-machine Interface Parameters
08-00
User password
Factory setting
0
Setting range 0
~
65535
08-00 sets any non-zero number, the password protection function takes effect. The next time you enter the menu,
you must enter the password correctly, otherwise you cannot view and modify the function parameters, please
remember the set user password.
Set 08-00 to 00000, then clear the set user password and invalidate the password protection function.
Summary of Contents for S3100A Series
Page 1: ...S3100Aseries inverter General Open loop Vector Control IM User manual User Manual ...
Page 24: ...20 Size 5 Unit mm S3100A 4T45G 55P 4T110G Size 6 Unit mm S3100A 4T110G 132P 4T160G 185P ...
Page 25: ...21 Size 7 Unit mm S3100A 4T185G 200P 4T220G Size 8 Unit mm S3100A 4T220G 250P 4T315G ...
Page 26: ...22 Size 9 Unit mm S3100A 4T315G 355P 4T400G 450P Size 10 Unit mm S3100A 4T450G 500P 4T500G ...