457
Error Message 1003 (Parity Error)
When there is an error with the product, the error message appears on the screen.
Tap the error number button to show the details screen.
Check the cause and countermeasure, and then take appropriate action.
To clear the error:
Tap [CLEAR] or tap [SETTINGS] to adjust the settings.
Cause and Countermeasure
Reference
Cause (1)
RS-232C settings are incorrect.
Countermeasure (1)
Set the interface settings of the product again.
Cause (2)
The RS-232C cable is not connected
correctly.
Countermeasure (2)
Power off the product, connect the RS-232C
cable correctly, and then power on the product
again.
RS-232C Interface Connection (Optional)
Contact your SATO technical support if the error cannot be resolved.