Replacing the Platen Roller
448
Replacing the Platen Roller
You can easily remove and replace a damaged or worn platen roller.
•
Do not connect or disconnect the power cord while your hands are wet. Doing so could
cause an electric shock.
•
Disconnect the power cord from the AC outlet before you replace the platen roller.
1. Make sure that the product is powered off, and disconnect the power cord from the
AC outlet.
2. Press the cover open latch (1) to open the top cover (2).
3. Remove the media if it is already loaded.
4. Raise the 2 levers (4) of the platen roller (3) to remove the platen roller.