PROGRAMMING GUIDE
SINUS PENTA
65
/
486
8.6. Outputs Menu
This menu allows checking the status of the digital outputs, the analog outputs and the frequency outputs located in the
terminal board.
M056 Digital Outputs
M056
Range
Bit-controlled measure.
Active
Always active.
Address
1706
Function
Status of digital outputs MDO1
÷
4 and status of the precharge contactor.
Table 5: Coding of Measure M056
Bit n.
Digital Output
0
MDO1/FOUT
1
MDO2
2
MDO3
3
MDO4
6
Status of the precharge
contactor
M056a Virtual Digital Outputs
M056a
Range
Bit-controlled measure.
Active
Always active.
Address
1675
Function
Status of virtual digital outputs MPL1
÷
4.
Table 6: Coding of Measure M056a
Bit n.
Digital Output
0
MPL1
1
MPL2
2
MPL3
3
MPL4
M056b Timed Flags
M056b
Range
Bit-controlled measure See Table 7
Active
Always active.
Address
1741
Function
Status of timed flags TFL1
÷
4.
Table 7: Coding of Measure M056b
Bit n.
Timed Flag
0
TFL1
1
TFL2
2
TFL3
3
TFL4